technostat | technostat performance

TECHNOSTAT PERFORMANCE

Penetration

Click here for a PDF of this chart

Airflow resistance

Click here for a PDF of this chart

Technostat - Typical Test Data
Technostat Needled to 15 g/m² spunbond polypropylene

Test Flow: 95 l/min on 100 cm²
 
Technostat grade Basis Weight
g/m²
Thickness*
mm
 
Resistance
Pa
Penetration**
EN13274-7 NaCl Aerosol
T30/15 45 0.9 3.5   60%
T50/15 65 1.3 5.0 31%
T70/15 85 1.6 6.9 18.6%
T100/15 115 2.0 9.9   10.2%
T150/15 165 2.5 16.5   3.9%
T200/15 215 3.0 23.8 1.9%
T250/15 265 3.3 32.1 1.1%
T300/15 315 3.6 40.8 0.72%
T350/15 365 4.1 48.6 0.51%
T400/15 415 4.3 58.4 0.39%
T450/15 465 4.7 67.8 0.29%
T500/15 515 5.1 78.0 0.19%

* Test pressure 1.6 kPa
** Aged material

 

TECHNOSTAT PLUS PERFORMANCE

Penetration

Click here for a PDF of this chart

Airflow resistance

 

Click here for a PDF of this chart

Technostat Plus - Typical Test Data
Technostat Needled to 15 g/m² spunbond polypropylene

Test Flow: 95 l/min on 100 cm²
 
Technostat grade Basis Weight
g/m²
Thickness*
mm
 
Resistance
Pa
Penetration**
EN13274-7 NaCl Aerosol
TPLUS 50/15 65 1.3 5.0   16%
TPLUS 70/15 85 1.6 8.0 10%
TPLUS 100/15 115 2.0 12.0 4%
TPLUS 150/15 165 2.6 20.0   1.8%
TPLUS 200/15 215 3.2 29.0   0.8%
TPLUS 250/15 265 3.5 38.0 0.5%
TPLUS 300/15 315 4.0 47.0 0.3%
TPLUS 400/15 415 5.0 67.0 0.15%
TPLUS 500/15 515 6.0 89.0 0.1%

* Test pressure 1.6 kPa
** Aged material

 

COMPARISON

Penetration

Click here for a PDF of this chart

Airflow resistance

Click here for a PDF of this chart

home | what's new | profile | applications | production | Technostat | policies | services | contact us               

Hollingsworth and Vose

Hollingsworth & Vose Air Filteration Ltd. Waterford Bridge Kentmere Cumbria LA8 9JJ UK

Tel: +44 (0)1539 825 200    Fax: +44 (0)1539 825 201    Email: enquiries@hvaf.co.uk